There is a new version of this product available. Check out the 315D/322D High-Speed Length Controllers!
315C/322C: High-Speed Length Controllers
The 315D and 322D High-Speed Length Controllers gives physiologists the ability to control and measure length of single cells, fibers and whole muscle with ease. Highly sensitive motors allow complete automated control of length of a vast number of biological specimens such as skeletal, cardiac and smooth muscle, connective tissue, and compliant tissue.
These motors provide a range of length control and response times uniquely suited to the needs of the researcher. Our fastest model, the 315D, provides a step change of length in 350µs and a length frequency response up to 1.7 kHz. All models allow the researcher to resolve length changes as small as 1 micron. All models have less than 0.01 micron/mN isometric compliance. With tensile limits of 100mN (315D) and 200mN (322D), respectively, our high-speed length controllers have more than enough force for any tissue sample.
The front panel manual length control allows the researcher to set the steady-state arm position. In addition, circuit design prevents the motor from being operated beyond its safe limits.
Models
315D: 100mN Force, Ultra low isometric compliance
322D: 200mN Force, Ultra low isometric compliance
Related Products
400B: Force Transducers
The 400C series of force transducers is the next generation of our widely used 400A series.
Learn More600A: Real-Time Muscle Data Acquisition and Analysis System
The 600A Digital Controller serves to integrate components and provide the researcher control of system operations, data collection and signal analysis.
Learn More605A: Dynamic Muscle Data Acquisition and Analysis System
Precise, custom software designed for real-time data acquisition, instrument control and data analysis with unique, integrative features. Includes force and SL control capability
Learn More701C: Electrical Stimulator
Our high-powered, bi-phase stimulator designed for muscle researchers conducting the most demanding field stimulation protocols.
Learn More801C: Small Intact Muscle Apparatus – Microscope Mountable
Highly integrated apparatus, optimally designed to test small, intact muscle contractility
Learn More802D: Permeabilized Fiber Apparatus – Microscope Mountable
A multi-well automated test system for quick and accurate measurement of permeabilized fiber dynamics
Learn More803B: Permeabilized Myocyte Apparatus – Microscope Mountable
Innovative 8–well plate designed for quick cell attachment and measurement of myocyte mechanical properties
Learn MoreRelated Systems
Resources
Specifications
Length Specifications | 315D | 322D |
---|---|---|
Lever Arm Length [mm] | 9 | 20 |
Length Excursion [mm] | 3 | 6 |
Length Resolution [um] | 0.5 | 0.5 |
Length Scale Factor1 [mm/Volt ±2%] | 0.15 | 0.3 |
Length Signal Linearity2 [%] | 99.5 | 99.9 |
Length Step Response Time3 [millisecond] | 0.25 | 0.4 |
Sinusoidal Frequency Response4 [Hz] | 2,400 | 1,500 |
1 = Gain switch set to 1X; 2 = Over full length excursion; 3 = 1 to 99%, critically damped; 4 = -3dB point
Force Specifications | 315D | 322D |
---|---|---|
Maximum Force [mN] | 300 | 200 |
General Specifications | 315D | 322D |
---|---|---|
Power Required | 100, 120, 220, 240 VAC, 50/60 Hz. Available | |
Power Consumption [W] | 60 | 60 |
Controller Weight [kg] | 2.7 | 2.7 |
Motor Weight [g] | 27 | 43 |